Sec. 15.217 Operation in the band 160-190 kHz.
(a) The total input power to the final radio frequency stage
(exclusive of filament or heater power) shall not exceed one watt.
(b) The total length of the transmission line, antenna, and ground
lead (if used) shall not exceed 15 meters.
(c) All emissions below 160 kHz or above 190 kHz shall be attenuated
at least 20 dB below the level of the unmodulated carrier. Determination
of compliance with the 20 dB attenuation specification may be based on
measurements at the intentional radiator's antenna output terminal
unless the intentional radiator uses a permanently attached antenna, in
which case compliance shall be demonstrated by measuring the radiated
emissions.
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.