Sec. 73.664 Determining operating power.
(a) The operating power of each TV visual transmitter shall normally
be determined by the direct method.
(b) Direct method, visual transmitter. The direct method of power
determination for a TV visual transmitter uses the indications of a
calibrated transmission line meter (responsive to peak power) located at
the RF output terminals of the transmitter. The indications of the
calibrated meter are used to observe and maintain the authorized
operating power of the visual transmitter. This meter must be calibrated
whenever any component in the metering circuit is repaired or replaced
and as often as necessary to ensure operation in accordance with the
provisions of Sec. 73.1560 of this part. The following calibration
procedures are to be used:
(1) The transmission line meter is calibrated by measuring the
average power at the output terminals of the transmitter, including any
vestigial sideband and harmonic filters which may be used in normal
operation. For this determination the average power output is measured
while operating into a dummy load of substantially zero reactance and a
resistance equal to the transmission line characteristic impedance.
During this measurement the transmitter is to be modulated only by a
standard synchronizing signal with blanking level set at 75% of peak
amplitude as observed in an output waveform monitor, and with this
blanketing level amplitude maintained throughout the time interval
between synchronizing pulses.
(2) If electrical devices are used to determine the output power,
such devices must permit determination of this power to within an
accuracy of plus-minus5% of the power indicated by the full
scale reading of the electrical indicating instrument of the device. If
temperature and coolant flow indicating devices are used to determine
the power output, such devices must permit determination of this power
to within an accuracy of plus-minus4% of measured average
power output. The peak power output is the power so measured in the
dummy load multiplied by the factor 1.68. During this measurement the
input voltage and current to the final radio frequency amplifier stage
and the transmission line meter are to be read and compared with similar
readings taken with the dummy load replaced by the antenna. These
readings must be in substantial agreement.
(3) The meter must be calibrated with the transmitter operating at
80%, 100%, and 110% of the authorized power
[[Page 202]]
as often as may be necessary to maintain its accuracy and ensure correct
transmitter operating power. In cases where the transmitter is incapable
of operating at 110% of the authorized power output, the calibration may
be made at a power output between 100% and 110% of the authorized power
output. However, where this is done, the output meter must be marked at
the point of calibration of maximum power output, and the station will
be deemed to be in violation of this rule if that power is exceeded. The
upper and lower limits of permissible power deviation as determined by
the prescribed calibration, must be shown upon the meter either by means
of adjustable red markers incorporated in the meter or by red marks
placed upon the meter scale or glass face. These markings must be
checked and changed, if necessary, each time the meter is calibrated.
(c) Indirect method, visual transmitter. The operating power is
determined by the indirect method by applying an appropriate factor to
the input power to the final radio-frequency amplifier stage of the
transmitter using the following formula:
Transmitter output power=Ep x Ip x F
Where:
Ep=DC input voltage of the final radio-frequency amplifier stage.
Ip=DC input current of the final radio-frequency amplifier stage.
F=Efficiency factor.
(1) If the above formula is not appropriate for the design of the
transmitter final amplifier, use a formula specified by the transmitter
manufacturer with other appropriate operating parameters.
(2) The value of the efficiency factor, F established for the
authorized transmitter output power is to be used for maintaining the
operating power, even though there may be some variation in F over the
power operating range of the transmitter.
(3) The value of F is to be determined and a record kept thereof by
one of the following procedures listed in order of preference:
(i) Using the most recent measurement data for calibration of the
transmission line meter according to the procedures described in
paragraph (b) of this section or the most recent measurements made by
the licensee establishing the value of F. In the case of composite
transmitters or those in which the final amplifier stages have been
modified pursuant to FCC approval, the licensee must furnish the FCC and
also retain with the station records the measurement data used as a
basis for determining the value of F.
(ii) Using measurement data shown on the transmitter manufacturer's
test data supplied to the licensee, provided that measurements were made
at the authorized carrier frequency and transmitter output power.
(iii) Using the transmitter manufacturer's measurement data
submitted to the FCC for type acceptance as shown in the instruction
book supplied to the licensee.
Note: Refer to Sec. 73.1560 for aural transmitter output power
levels.
[ 44 FR 58732 , Oct. 11, 1979, as amended at 48 FR 44805 , Sept. 30, 1983;
49 FR 4210 , Feb. 3, 1984; 49 FR 22092 , May 25, 1984; 49 FR 49851 , Dec.
24, 1984; 50 FR 26568 , June 27, 1985; 54 FR 9806 , Mar. 8, 1989.
Redesignated at 58 FR 62555 , Nov. 29, 1993]
Goto Section: 73.658 | 73.665
Goto Year: 1996 |
1998
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public