Sec. 80.921 Proof of capacity.
(a) When directed by a representative of the Commission the vessel
must prove by demonstration as prescribed in paragraphs (b), (c), (d)
and (e) of this section, that the requirements of Sec. 80.919 are met.
(b) Proof of the ability of a storage battery used as a main or
reserve power supply to operate over the 3-hour period established by a
discharge test over the prescribed period of time, when supplying power
at the voltage required for an electrical loss as prescribed by
paragraph (d) of this section.
(c) When the required power supply consists of an engine-driven
generator, proof of the adequacy of the engine fuel supply to operate
the unit over the 3-hour period of time may be established by using as a
basis the fuel consumption during a 1 hour period when supplying power,
at the voltage required for operating an electrical load as prescribed
by paragraph (d) of this section.
(d) In determining the required electrical load the following
formula must be used:
(1) One-half of the current of the required transmitter at its rated
output power; plus
(2) Current of the required receiver; plus
(3) Current of electric light, if required by Sec. 80.925; plus
(4) The sum of the current of all other loads the reserve power
supply may provide in time of emergency.
(e) At the conclusion of the test specified in paragraphs (b) and
(c) of this section, no part of the main or reserve power supply must
have an excessive temperature rise, nor must the specific gravity or
voltage of any storage battery be below the 90 percent discharge point.
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.