Sec. 90.215 Transmitter measurements.
(a) The licensee of each station shall employ a suitable procedure
to determine that the carrier frequency of each transmitter authorized
to operate with an output power in excess of two watts is maintained
within the tolerence prescribed in Sec. 90.213. This determination shall
be made, and the results entered in the station records in accordance
with the following:
(1) When the transmitter is initially installed;
(2) When any change is made in the transmitter which may affect the
carrier frequency or its stability.
(b) The licensee of each station shall employ a suitable procedure
to determine that each transmitter authorized to operate with an output
power in excess of two watts does not exceed the maximum figure
specified on the current station authorization. On authorizations
stating only the input power to the final radiofrequency stage, the
maximum permissible output power is 75 percent for frequencies below 25
MHz and 60 percent of the input power for frequencies above 25 MHz. If a
non-DC final radiofrequency stage is utilized, then the output power
shall not exceed 75 percent of the input power. This determination shall
be made, and the results thereof entered into the station records, in
accordance with the following:
(1) When the transmitter is initially installed;
(2) When any change is made in the transmitter which may increase
the transmitter power input.
(c) The licensee of each station shall employ a suitable procedure
to determine that the modulation of each transmitter, which is
authorized to operate with an output power in excess of two watts, does
not exceed the limits specified in this part. This determination shall
be made and the following results entered in the station records, in
accordance with the following:
(1) When the transmitter is initially installed;
(2) When any change is made in the transmitter which may affect the
modulation characteristics.
(d) The determinations required by paragraphs (a), (b), and (c) of
this section may, at the opinion of the licensee, be made by a qualified
engineering measurement service, in which case the required record
entries shall show the name and address of the engineering measurement
service as well as the name of the person making the measurements.
(e) In the case of mobile transmitters, the determinations required
by paragraphs (a) and (c) of this section
[[Page 467]]
may be made at a test or service bench: Provided, That the measurements
are made under load conditions equivalent to actual operating
conditions; and provided further, that after installation in the mobile
unit the transmitter is given a routine check to determine that it is
capable of being received satisfactorly by an appropriate receiver.