Sec. 90.689 Field strength limits.
(a) For purposes of implementing Secs. 90.689 through 90.699,
predicted 36 and 40 dBV/m contours shall be calculated using
Figure 10 of Sec. 73.699 of this chapter with a correction factor of -9
dB, and predicted 18 and 22 dBV/m contours shall be calculated
using Figure 10a of Sec. 73.699 of this chapter with a correction factor
of -9 dB.
(b) The predicted or measured field strength at any location on the
border of the EA-based service area for EA licensees must not exceed 40
dBuV/m unless all bordering EA licensees agree to a higher field
strength. In the event that this standard conflicts with the EA
licensee's obligation to provide co-channel protection to incumbent
licensees pursuant to Sec. 90.621(b), the requirements of Sec. 90.621(b)
shall prevail.
[ 61 FR 6158 , 6159, Feb. 16, 1996, as amended at 62 FR 41216 , July 31,
1997]