Sec. 95.855 Transmitter effective radiated power limitation.
(a) The effective radiated power (ERP) of each CTS and RTU shall be
limited to the minimum necessary for successful communications. RTUs
with powers in excess of 100 milliwatts must incorporate automatic power
control to ensure the minimum ERP is used. No CTS may transmit with an
ERP exceeding 20 watts. No fixed RTU may transmit with an ERP exceeding
20 watts. No mobile RTU may transmit with an ERP exceeding 100
milliwatts mean power.
(b) For an IVDS system located in a TV Channel 13 station Grade B
predicted contour, the maximum ERP shall be limited as follows:
------------------------------------------------------------------------
Maximum CTS
TV channel 13 service area ERP (watts)
------------------------------------------------------------------------
City Grade................................................. 20
Grade A.................................................... 7
Grade B.................................................... 1
Grade B +2 miles........................................... 1
Grade B +3 miles........................................... 3
Grade B +4 miles........................................... 10
Grade B +5 miles and beyond................................ 20
[[Page 671]]
------------------------------------------------------------------------
[ 57 FR 8275 , Mar. 9, 1992, as amended at 61 FR 32711 , June 25, 1996]