Goto Section: 17.219 | 17.223

FCC 17.221
Revised as of June 29, 2005
Goto Year:2004 | 2006
Sec.  15.221   Operation in the band 525-1705 kHz.

   

   (a) Carrier current systems and transmitters employing a leaky coaxial
   cable as the radiating antenna may operate in the band 525-1705 kHz
   provided the field strength levels of the radiated emissions do not
   exceed 15 uV/m, as measured at a distance of 47,715/(frequency in kHz)
   meters (equivalent to Lambda/2Pi) from the electric power line or the
   coaxial cable, respectively. The field strength levels of emissions
   outside this band shall not exceed the general radiated emission
   limits in Sec. 15.209.

   (b) As an alternative to the provisions in paragraph (a) of this
   section, intentional radiators used for the operation of an AM
   broadcast station on a college or university campus or on the campus
   of any other education institution may comply with the following:

   (1) On the campus, the field strength of emissions appearing outside
   of this frequency band shall not exceed the general radiated emission
   limits shown in Sec. 15.209 as measured from the radiating source. There
   is no limit on the field strength of emissions appearing within this
   frequency band, except that the provisions of Sec. 15.5 continue to
   comply.

   (2) At the perimeter of the campus, the field strength of any
   emissions, including those within the frequency band 525-1705 kHz,
   shall not exceed the general radiated emission in Sec. 15.209.

   (3) The conducted limits specified in Sec. 15.207 apply to the radio
   frequency voltage on the public utility power lines outside of the
   campus. Due to the large number of radio frequency devices which may
   be used on the campus, contributing to the conducted emissions, as an
   alternative to measuring conducted emissions outside of the campus, it
   is acceptable to demonstrate compliance with this provision by
   measuring each individual intentional radiator employed in the system
   at the point where it connects to the AC power lines.

   (c) A grant of equipment authorization is not required for intentional
   radiators operated under the provisions of this section. In lieu
   thereof, the intentional radiator shall be verified for compliance
   with the regulations in accordance with subpart J of part 2 of this
   chapter. This data shall be kept on file at the location of the
   studio, office or control room associated with the transmitting
   equipment. In some cases, this may correspond to the location of the
   transmitting equipment.

   (d) For the band 535-1705 kHz, the frequency of operation shall be
   chosen such that operation is not within the protected field strength
   contours of licensed AM stations.

   [ 56 FR 373 , Jan. 4, 1991]


Goto Section: 17.219 | 17.223

Goto Year: 2004 | 2006
CiteFind - See documents on FCC website that cite this rule

Report errors in this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public