Goto Section: 22.757 | 22.801 | Table of Contents
FCC 22.759
Revised as of October 1, 2005
Goto Year:2004 |
2006
Sec. 22.759 Power limit for BETRS.
The effective radiated power of central office and rural subscriber station
transmitters used in basic exchange telephone radio systems must not exceed
the limits in this section.
(a) Maximum ERP. The effective radiated power (ERP) of central office and
rural subscriber station transmitters in BETRS must not exceed the
applicable limits in this paragraph under any circumstances.
------------------------------------------------------------------------
Maximum ERP
Frequency range (MHz) (watts)
------------------------------------------------------------------------
152-153.................................................... 1400
157-159.................................................... 150
454-455.................................................... 3500
459-460.................................................... 150
------------------------------------------------------------------------
(b) Height-power limit. The ERP of central office stations in BETRS must not
exceed the amount calculated as follows:
ERP[w]=557,418÷h[m]2
where ERP[w] is the effective radiated power in Watts
h[m] is the average (eight cardinal radial) antenna height above average
terrain in meters
Subpart G—Air-Ground Radiotelephone Service
Goto Section: 22.757 | 22.801
Goto Year: 2004 |
2006
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public