FCC 15.201 Revised as of October 1, 2006
Goto Year:2005 |
2007
Sec. 15.201 Equipment authorization requirement.
(a) Intentional radiators operated as carrier current systems, devices
operated under the provisions of Sec. Sec. 15.211, 15.213, and 15.221, and devices
operating below 490 kHz in which all emissions are at least 40 dB below the
limits in Sec. 15.209 shall be verified pursuant to the procedures in Subpart J
of part 2 of this chapter prior to marketing.
(b) Except as otherwise exempted in paragraph (c) of this section and in
Sec. 15.23 of this part, all intentional radiators operating under the
provisions of this part shall be certificated by the Commission pursuant to
the procedures in subpart J of part 2 of this chapter prior to marketing.
(c) For devices such as perimeter protection systems which, in accordance
with Sec. 15.31(d), are required to be measured at the installation site, each
application for certification must be accompanied by a statement indicating
that the system has been tested at three installations and found to comply
at each installation. Until such time as certification is granted, a given
installation of a system that was measured for the submission for
certification will be considered to be in compliance with the provisions of
this chapter, including the marketing regulations in subpart I of part 2 of
this chapter, if tests at that installation show the system to be in
compliance with the relevant technical requirements. Similarly, where
measurements must be performed on site for equipment subject to
verification, a given installation that has been verified to demonstrate
compliance with the applicable standards will be considered to be in
compliance with the provisions of this chapter, including the marketing
regulations in subpart I of part 2 of this chapter.
(d) For perimeter protection systems operating in the frequency bands
allocated to television broadcast stations operating under part 73 of this
chapter, the holder of the grant of certification must test each
installation prior to initiation of normal operation to verify compliance
with the technical standards and must maintain a list of all installations
and records of measurements. For perimeter protection systems operating
outside of the frequency bands allocated to television broadcast stations,
upon receipt of a grant of certification, further testing of the same or
similar type of system or installation is not required.
[ 54 FR 17714 , Apr. 25, 1989, as amended at 68 FR 68546 , Dec. 9, 2003]
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.