Sec. 15.229 Operation within the band 40.66–40.70 MHz.
(a) Unless operating pursuant to the provisions in Sec. 15.231, the field
strength of any emissions within this band shall not exceed 1,000
microvolts/meter at 3 meters.
(b) As an alternative to the limit in paragraph (a) of this section,
perimeter protection systems may demonstrate compliance with the following:
the field strength of any emissions within this band shall not exceed 500
microvolts/meter at 3 meters, as determined using measurement
instrumentations employing an average detector. The provisions in Sec. 15.35 for
limiting peak emissions apply where compliance of these devices is
demonstrated under this alternative emission limit.
(c) The field strength of any emissions appearing outside of this band shall
not exceed the general radiated emission limits in Sec. 15.209.
(d) The frequency tolerance of the carrier signal shall be maintained within
±0.01% of the operating frequency over a temperature variation of −20
degrees to +50 degrees C at normal supply voltage, and for a variation in
the primary supply voltage from 85% to 115% of the rated supply voltage at a
temperature of 20 degrees C. For battery operated equipment, the equipment
tests shall be performed using a new battery.
[ 54 FR 17714 , Apr. 25, 1989, as amended at 55 FR 33910 , Aug. 20, 1990]
Goto Section: 15.227 | 15.231
Goto Year: 2005 |
2007
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public