Goto Section: 1.1309 | 1.1311 | Table of Contents
FCC 1.1310
Revised as of October 1, 2010
Goto Year:2009 |
2011
§ 1.1310 Radiofrequency radiation exposure limits.
The criteria listed in table 1 shall be used to evaluate the
environmental impact of human exposure to radiofrequency (RF) radiation
as specified in § 1.1307(b), except in the case of portable devices
which shall be evaluated according to the provisions of § 2.1093 of
this chapter. Further information on evaluating compliance with these
limits can be found in the FCC's OST/OET Bulletin Number 65,
"Evaluating Compliance with FCC-Specified Guidelines for Human Exposure
to Radiofrequency Radiation."
Note to Introductory Paragraph: These limits are generally based on
recommended exposure guidelines published by the National Council on
Radiation Protection and Measurements (NCRP) in "Biological Effects and
Exposure Criteria for Radiofrequency Electromagnetic Fields," NCRP
Report No. 86, Sections 17.4.1, 17.4.1.1, 17.4.2 and 17.4.3. Copyright
NCRP, 1986, Bethesda, Maryland 20814. In the frequency range from 100
MHz to 1500 MHz, exposure limits for field strength and power density
are also generally based on guidelines recommended by the American
National Standards Institute (ANSI) in Section 4.1 of "IEEE Standard
for Safety Levels with Respect to Human Exposure to Radio Frequency
Electromagnetic Fields, 3 kHz to 300 GHz," ANSI/IEEE C95.1-1992,
Copyright 1992 by the Institute of Electrical and Electronics
Engineers, Inc., New York, New York 10017.
Table 1--Limits for Maximum Permissible Exposure (MPE)
Frequency range
(MHz) Electric field strength
(V/m) Magnetic field strength
(A/m) Power density
(mW/cm^2) Averaging time
(minutes)
(A) Limits for Occupational/Controlled Exposures
0.3-3.0 614 1.63 *(100) 6
3.0-30 1842/f 4.89/f *(900/f^2) 6
30-300 61.4 0.163 1.0 6
300-1500 f/300 6
1500-100,000 5 6
(B) Limits for General Population/Uncontrolled Exposure
0.3-1.34 614 1.63 *(100) 30
1.34-30 824/f 2.19/f *(180/f^2) 30
30-300 27.5 0.073 0.2 30
300-1500 f/1500 30
1500-100,000 1.0 30
f = frequency in MHz
* = Plane-wave equivalent power density
Note 1 to Table 1: Occupational/controlled limits apply in situations
in which persons are exposed as a consequence of their employment
provided those persons are fully aware of the potential for exposure
and can exercise control over their exposure. Limits for
occupational/controlled exposure also apply in situations when an
individual is transient through a location where
occupational/controlled limits apply provided he or she is made aware
of the potential for exposure.
Note 2 to Table 1: General population/uncontrolled exposures apply in
situations in which the general public may be exposed, or in which
persons that are exposed as a consequence of their employment may not
be fully aware of the potential for exposure or can not exercise
control over their exposure.
[ 61 FR 41016 , Aug. 7, 1996]
Goto Section: 1.1309 | 1.1311
Goto Year: 2009 |
2011
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public