Goto Section: 15.217 | 15.221 | Table of Contents
FCC 15.219
Revised as of October 1, 2016
Goto Year:2015 |
2017
§ 15.219 Operation in the band 510-1705 kHz.
(a) The total input power to the final radio frequency stage (exclusive
of filament or heater power) shall not exceed 100 milliwatts.
(b) The total length of the transmission line, antenna and ground lead
(if used) shall not exceed 3 meters.
(c) All emissions below 510 kHz or above 1705 kHz shall be attenuated
at least 20 dB below the level of the unmodulated carrier.
Determination of compliance with the 20 dB attenuation specification
may be based on measurements at the intentional radiator's antenna
output terminal unless the intentional radiator uses a permanently
attached antenna, in which case compliance shall be deomonstrated by
measuring the radiated emissions.
return arrow Back to Top
Goto Section: 15.217 | 15.221
Goto Year: 2015 |
2017
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public