Goto Section: 78.107 | 78.109 | Table of Contents
FCC 78.108
Revised as of September 1, 2021
Goto Year:2020 |
2022
§ 78.108 Minimum path lengths for fixed links.
(a) The distance between end points of a fixed link must equal or
exceed the value set forth in the table below or the EIRP must be
reduced in accordance with the equation set forth below.
Frequency band (MHz) Minimum path length (km)
12,200 to 13,250 5
Above 17,700 N/A
(b) For paths shorter than those specified in the Table, the EIRP shall
not exceed the value derived from the following equation.
EIRP = MAXEIRP − 40 log(A/B) dBW
Where:
EIRP = The new maximum EIRP (equivalent isotropically radiated power)
in dBW.
MAXEIRP = Maximum EIRP as set forth in the Table in § 74.636 of this
part.
A = Minimum path length from the Table above for the frequency band in
kilometers.
B = The actual path length in kilometers.
Note to paragraph (b): For transmitters using Automatic Transmitter
Power Control, EIRP corresponds to the maximum transmitter power
available, not the coordinated transmit power or the nominal transmit
power.
(c) Upon an appropriate technical showing, applicants and licensees
unable to meet the minimum path length requirement may be granted an
exception to these requirements.
Note: Links authorized prior to April 1, 1987, are excluded from this
requirement, except that, effective April 1, 1992, the Commission will
require compliance with the criteria where an existing link would
otherwise preclude establishment of a new link.
[ 52 FR 7145 , Mar. 9, 1987, as amended at 68 FR 12776 , Mar. 17, 2003]
Goto Section: 78.107 | 78.109
Goto Year: 2020 |
2022
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public